Type 2500/F Safety Relief Valve |
|||
| Product Overview | |||
The Type 2500/F Relief/Safety Relief valves are used for low capacities, and for pressures up to 344 Barg on gas, steam and liquid service. The minimum set pressure is 0.70 Barg. Valves are supplied in sizes three quarter inch x one inch to two inch x two inch and can be manufactured in Cast Steel, Stainless Steel and Gunmetal with ends screwed female x female, male x female or flanged to customers requirements. Valves can also be supplied with a packed lever lifting device, limit switch to indicate opening and closing of the valve, governing ring to limit adjustment of the spring to the set point, for ease of re-setting. |
|||
| Specification | |||
|
Contact Sales for more information |
|||
| Description of Action | |||
Contact Sales for more information |
|||
| Installation Instructions | |||
During installation of the valve avoid bumping or shaking to prevent damaging the flange faces and misalignment of the trim. Blow through the circuit line on which the valve is to be installed, this is to remove any foreign bodies. Clean the valve and nozzle connections thoroughly; foreign bodies on the nozzle may damage the valve seat during popping. Install the valve in a vertical position only, with the inlet downwards. After the valve has been installed make it pop at least twice to allow automatic alignment of the trim. Misalignment may be caused accidentally during transport or during installation. |
|||
| Maintenance Information | |||
|
|||
| Download the Datasheet here: | Download the IOM here: | ||
| Product Image | |||